AHU Dezenno.MAX: A Comprehensive Air Handling Solution for Modern Airports
07/06/2025
An airport is not just a key transportation hub but a "mini-city" that never sleeps. With millions of passengers annually, 24/7 continuous operation, and complex functional areas, ensuring a fresh, safe, and comfortable air environment is a vital factor that directly impacts passenger experience and operator reputation, as assessed by prestigious organizations like the Airports Council International (ACI).
The heart of this intricate HVAC (Heating, Ventilation, and Air Conditioning) system is the Air Handling Unit (AHU). Deeply understanding these challenges, DeAir introduces the AHU Dezenno.MAX product line – a tailor-made solution with advanced technology that meets the most stringent international standards specifically for the unique airport environment.
DeAir's Dezenno.MAX AHU used in airports, meeting international standards
Specific Requirements for Airport AHU Systems
Airport AHU systems face some of the most unique and demanding requirements, far exceeding those of typical commercial applications:
Massive Cooling Load and Airflow: Lobbies, check-in areas, and corridors are vast spaces requiring high-capacity AHUs to ensure air is circulated and cooled evenly.
Strict Indoor Air Quality (IAQ) Control: The huge flow of people from around the world brings risks of bacteria and viruses. AHUs must be able to filter fine dust (PM2.5, PM1.0), allergens, and effectively control CO2 levels.
Continuous 24/7/365 Operation: The equipment must have absolute reliability, durable materials, and a design that allows for easy maintenance without disrupting operations.
Energy Cost Optimization: The HVAC system accounts for 40-60% of an airport's total electricity costs. Therefore, an energy-saving system is a critical economic consideration.
Precise Humidity Control: Especially in Vietnam's hot and humid climate, AHUs need to effectively dehumidify to prevent condensation on large glass walls, protect interiors and electronic equipment, and provide comfort for passengers.
Low Noise Levels: Ensuring quiet and luxury in key areas such as business lounges and rest areas.
Safety and Durability: Materials must meet fire safety standards and be corrosion-resistant, especially at coastal airports exposed to salt spray.
Dezenno.MAX AHU meets the 7 specific requirements of an airport AHU system
Dezenno.MAX DeAir - The Comprehensive Solution for Airport HVAC Systems
The Dezenno.MAX AHU is designed to thoroughly address the above challenges, providing a comprehensive and efficient air handling solution.
Reasons why Dezenno.MAX AHU is the comprehensive solution for airport HVAC systems
Flexible Modular Design, Meeting Any Scale
Each area in an airport has different requirements. Dezenno.MAX's modular block design allows for flexible configuration: from airflow and cooling/heating capacity to filtration levels and functions like heat recovery and dehumidification. This ensures each AHU is optimized for its specific location, from bustling check-in halls to quiet air traffic control towers, optimizing both performance and investment costs.
Superior Energy Efficiency with Advanced Technology
DeAir prioritizes energy savings in every aspect of the Dezenno.MAX design:
Heat Recovery Wheel (HRW): The optional integration of a Heat Recovery Wheel can recover 70-80% of the energy from exhaust air, significantly reducing the load on the central Chiller system.
Anti-Thermal-Loss Panel Casing: The AHU casing is made from high-density (40-45 kg/m³) Polyurethane (PU) panels, 50mm thick, with a thermal break aluminum frame design, which almost completely eliminates thermal bridging and prevents energy loss.
Multi-Stage Filtration System, Ensuring International Standard Clean Air
To ensure the highest level of Indoor Air Quality (IAQ), the Dezenno.MAX AHU can integrate a multi-stage filtration system that complies with the ASHRAE 62.1 standard:
Stage 1: G4 pre-filter removes large dust, hair, and insects.
Stage 2: F7/F8 fine filter removes fine dust and pollen.
Stage 3: HEPA H13/H14 filter (optional) for areas requiring sterile conditions, such as a clean room, capable of capturing 99.99% of ultra-fine particles and bacteria.
Stage 4: Activated carbon filter (optional) to remove odors and volatile organic compounds (VOCs).
Precise Humidity Control - Integrated DeAir Solution
The Dezenno.MAX AHU uses a cooling coil with a large surface area and appropriate air velocity to optimize moisture removal from the air. For areas with extremely low humidity requirements or harsh operating conditions, DeAir can integrate specialized industrial rotor dehumidifiers directly into the AHU system, providing precise humidity control down to 1%.
Durable, Reliable & Corrosion-Resistant Operation
Designed for an operational lifespan of over 20 years, the Dezenno.MAX features a robust construction with a high-grade aluminum profile frame and a casing of galvanized steel or Stainless Steel 304/316. Especially for coastal airport projects (Da Nang, Cam Ranh, Phu Quoc, Van Don), DeAir offers an optional Epoxy coating for the entire casing and metal parts, creating a perfect protective layer against salt spray corrosion.
Smart Control System Integration (BMS)
The Dezenno.MAX AHU is ready to connect with the Building Management System (BMS) through common protocols like Modbus or BACnet. This allows the central control center to monitor and command the entire AHU system remotely, track operating parameters (temperature, humidity, CO2, pressure...), optimize operating schedules, and receive early fault alerts, ensuring the system always operates stably and efficiently.
Comparison Table: Dezenno.MAX AHU Solutions for Different Airport Zones
Zone
Main Requirement
Customized Dezenno.MAX AHU Solution
Arrival/Departure & Check-in Halls
High airflow, basic dust filtration
High-airflow AHU configuration, G4 + F8 filters, heat recovery wheel.
Lounges, VIP Rooms
Ultra-low noise, high IAQ, comfort
Low-speed EC fan operation, integrated sound attenuators, HEPA filter, CO2 sensor.
Retail, Dining Areas
Odor removal, high cooling load, fire safety
Integration of activated carbon filter, high-capacity cooling coil, fire-retardant materials.
High-grade filtration, fan control system to maintain pressure differential.
Dezenno.MAX AHU solutions for different zones in an airport
Why Choose DeAir as the AHU Solution Partner for Your Airport Project?
In-depth Experience & Expertise: DeAir's engineering team has a deep understanding of international HVAC standards and the specific requirements for large-scale projects like airports.
High-Quality Components: DeAir is committed to using only components and equipment from leading, reputable manufacturers in Europe and around the world, ensuring the highest reliability and performance.
Quality Commitment: DeAir's entire production and management process strictly adheres to the ISO 9001:2015 international standard.
Conclusion
Choosing an AHU system for an airport is a strategic investment decision. Investing in the AHU Dezenno.MAX is not just an investment in mechanical equipment, but an investment in the safety, health, and satisfaction of millions of passengers, while also optimizing operational costs and enhancing the prestige and class of the facility.
For in-depth technical consultation and a custom-designed AHU Dezenno.MAX solution for your airport project, contact the experts at DeAir today.